    Steve on How to calibrate the temperature on your iAqualink Unit.Luis on How to calibrate the temperature on your iAqualink Unit.Shared iPadOS TemporarySessionTimeout Experience June 2, 2022.AAA Shady Automatic Renewal Practice June 14, 2022.Put Dates on Everything January 23, 2023.Tankless Water Heater 16 years on April 27, 2023.Is this complete cycle happening? Can you see a orange-red glow at the site glass on top of the burner box? The heater should try to ignite and sense flame 2 times then shut down with IGN Fault each time you try to start it. Before 7 seconds the ignition module must detect a minute (million's of an amp) flame-sense current through the ground circuit. Then you hear the gas valve open and ignition occurs. After 15 sec the igniter is turned on and you'll see a faint then strong orange glow through the igniter window. Then the blower starts and the ignition module checks pressure senor. Then the control board checks for hi/lo temp, water pressure, vent fire sensor, then it issues "call for heat" to the ignition control. The normal sequence after you turn on the heater is the temp setting is detected above the actual temp.

    jandy pool control panel reset

    In the video did it ever ignite a flame? I hear the blower but I don't hear ignition or was it already ignited?.

    #JANDY POOL CONTROL PANEL RESET CODE#

    Is this happening or is the error code intermittent? Can you confirm the number of flashes that occur on the red light on the edge of the Fenwal ignition module? If not, how many times does it blink?

    jandy pool control panel reset

    PS Be sure you actually do have good flow and don't have a plugged filter or closed valve that limits flow The air pressure sensor is a little tricky since it must read one way at start and then close. Next step is to bypass the sensors one at a time to see if you have a bad sensor.

    jandy pool control panel reset

    Let me know if this does not work for you. I removed cleaned all the sensor contacts then replaced and coated with Corrosion Block. In my case it was a bad connection at the air pressure sensor mounted to the plastic housing on the rear of the fan. If that doesn't matter to you then remove the top panel then very carefully wiggle the connections during the start sequence at each of the sensors mentioned above. If you are still in warranty you should call your installer since you can void your warranty by trouble shooting yourself. the stack temp fusible link that has failed from vent blockage or fire in the stackįirst thing to try is to reset power at the breaker.the pressure sensor on the back of the fan is indicating blocked air flow.the temperature sensors that check for high temp.the pressure sensor that checks for flow.You get this error when something in the heater start sequence has reported an unsafe condition. I had this exact same problem at about the same age on my Jandy Jxi.









    Jandy pool control panel reset